TW330
Tengyu
18L/Barrel, 20L/Barrel
Red ,Black etc
Availability: | |
---|---|
Quantity: | |
Solvent Based Polyurethane Waterproof coating is a single-component, high-solids polyurethane waterproofing membrane suitable for concrete, wood, and masonry. Ideal for retaining walls, below-grade waterproofing, and tunnels.
Base | Polyurethane |
Solid Content | 89% |
Skin Time | 6h |
Heavy traffic Time | 24h |
Tear Strength | 18N/mm |
Elongation at break % | 659% |
Tensile Strength | 3.06MPa |
Heating Shrinkage Rate | 0.8% |
Adhesive Strength | 1.2MPa |
Aging Test after Heating | PASS |
Water Absorption Rate | 3.1% |
Water-permeable test(120min,0.3MPa) | PASS |
1) Easy operation, no special requirements about base layer.
2) High tensile strength and elongation, excellent performance to high and low temperature.
3) Thickness can be 1-3mm one-time brushing, coating film is dense, no pinhole, no bubble.
4) Strong cohesive force, no need other chemical auxiliaries.
5) Color can be customized according to customers' specific requirements
1.Tiled or covered areas
2. Shower recess & wet areas (floors and upturns)
3. Structural slabs
4. Non-exposed roof
5. Underground&Balconies
6. Indoor bathroom and kitchen
7. Non-potable water waterproof construction
1. Surface Preparation: The base requires solid, flat, no debris, fully dry, interal and extermal cormers should be made in to acircular arc, the internal corners diameter greater than 50mm, and the external corners diameter greater than 10mm.
2. Application: According to the construction are, the reference dosage is: the dosage of 1mm thick coating film is about 1.3-1.5kg/m.
(1) Large area waterproof construction: the mixed material is evenly coated with roller or plastic scraper, the required thickness is 1.5mm to 2.0mm, it should be divided into 3-4 times, and in the vertical direction of brushing, generally a separate film, underground engineering floor should be added a layer of matrix reinforcement material.
(2)Film thickness: The underground engineering shall be 1.2mm-2.0mm, generally 1.5mm, and the toilet bath shall not be less than 1.5mm. When the exposed roof engineering adopts multi-channel waterproofing, the thickness of each channel shall not be less than 1.2mm. When the waterproof grade ill, the roof shall be waterproofed together, the waterproof thickness shall not be less than 2mm.The coating thickness below the matrixis not less than 1.0mm, and the coating above is not less than 0.5mm.
3. Protective layer: The surface of the waterproof coating layer should be isolated and protected according to the design requirements.
Store in the original sealed packaging at temperatures of between 0℃ and 30℃, this product is sensitive to frost and must be kept in tightly closed packaging.The shelf life is about 18 months when stored in a cool and dry place.
Keep out of reach of children. In case of contact with eyes, please rinse eyes with plenty of water and seek medical advice as soon as possible.
Solvent Based Polyurethane Waterproof coating is a single-component, high-solids polyurethane waterproofing membrane suitable for concrete, wood, and masonry. Ideal for retaining walls, below-grade waterproofing, and tunnels.
Base | Polyurethane |
Solid Content | 89% |
Skin Time | 6h |
Heavy traffic Time | 24h |
Tear Strength | 18N/mm |
Elongation at break % | 659% |
Tensile Strength | 3.06MPa |
Heating Shrinkage Rate | 0.8% |
Adhesive Strength | 1.2MPa |
Aging Test after Heating | PASS |
Water Absorption Rate | 3.1% |
Water-permeable test(120min,0.3MPa) | PASS |
1) Easy operation, no special requirements about base layer.
2) High tensile strength and elongation, excellent performance to high and low temperature.
3) Thickness can be 1-3mm one-time brushing, coating film is dense, no pinhole, no bubble.
4) Strong cohesive force, no need other chemical auxiliaries.
5) Color can be customized according to customers' specific requirements
1.Tiled or covered areas
2. Shower recess & wet areas (floors and upturns)
3. Structural slabs
4. Non-exposed roof
5. Underground&Balconies
6. Indoor bathroom and kitchen
7. Non-potable water waterproof construction
1. Surface Preparation: The base requires solid, flat, no debris, fully dry, interal and extermal cormers should be made in to acircular arc, the internal corners diameter greater than 50mm, and the external corners diameter greater than 10mm.
2. Application: According to the construction are, the reference dosage is: the dosage of 1mm thick coating film is about 1.3-1.5kg/m.
(1) Large area waterproof construction: the mixed material is evenly coated with roller or plastic scraper, the required thickness is 1.5mm to 2.0mm, it should be divided into 3-4 times, and in the vertical direction of brushing, generally a separate film, underground engineering floor should be added a layer of matrix reinforcement material.
(2)Film thickness: The underground engineering shall be 1.2mm-2.0mm, generally 1.5mm, and the toilet bath shall not be less than 1.5mm. When the exposed roof engineering adopts multi-channel waterproofing, the thickness of each channel shall not be less than 1.2mm. When the waterproof grade ill, the roof shall be waterproofed together, the waterproof thickness shall not be less than 2mm.The coating thickness below the matrixis not less than 1.0mm, and the coating above is not less than 0.5mm.
3. Protective layer: The surface of the waterproof coating layer should be isolated and protected according to the design requirements.
Store in the original sealed packaging at temperatures of between 0℃ and 30℃, this product is sensitive to frost and must be kept in tightly closed packaging.The shelf life is about 18 months when stored in a cool and dry place.
Keep out of reach of children. In case of contact with eyes, please rinse eyes with plenty of water and seek medical advice as soon as possible.
content is empty!